When baseboard heat or radiators won’t get hot, the cause is usually one of a handful of things: air trapped in the pipes, a zone that isn’t calling for heat, low pressure in the system, or a zone valve or circulator that has stopped working. Sometimes the boiler itself isn’t firing. Noble’s Heating & Cooling services oil, gas and propane boilers throughout the Lehigh Valley and the Poconos, from Saylorsburg to Easton, and many of the homes we work in have hot water heat. Here’s how to narrow down the problem and what you can safely check before you call.
Start With How Much of the House Is Cold
The pattern tells you a lot. Before touching anything, walk through the house and notice what’s warm and what isn’t.
- The whole house is cold. The boiler probably isn’t running. That points to power, the thermostat, fuel, or a safety control that has shut the burner down.
- One floor or one area is cold. Most hot water systems are split into zones, each with its own thermostat. If one zone is cold and the others are fine, the problem is usually that zone’s thermostat, zone valve or circulator.
- One radiator or one run of baseboard is cold. That usually means air in that section, a closed valve, or something blocking the heat from getting into the room.
Air in the Lines
Air rises to the high points in a hot water system and stops the water from circulating there. The signs are gurgling or trickling sounds in the pipes and radiators that are warm at the bottom but cold at the top.
Cast iron radiators usually have a small bleed valve near the top. With the heat off and the radiator cool, hold a cup and a rag under the valve, open it slowly with a radiator key, and close it as soon as water comes out instead of air. Many baseboard systems don’t have bleed valves at each room. They’re purged from valves near the boiler, which is usually a job for us.
If you find yourself bleeding the same radiators every few weeks, air is getting into the system for a reason. A failing expansion tank, a fill valve that isn’t working properly or a small leak are the usual suspects, and they’re worth finding before they cause bigger problems.
Look at the Pressure Gauge
Most hot water boilers have a combination gauge on the front or top that shows pressure and temperature. It helps to know where the needle normally sits when the system is cold. If the pressure is much lower than usual, the system may have lost water and won’t push heat to the upper floors. If the pressure keeps climbing until the relief valve on the side of the boiler starts to drip, something else is wrong. Either way, give us a call rather than adding water yourself, unless a technician has shown you how to do it on your system.
Thermostats, Zone Valves and Circulators
For a cold zone, start with its thermostat. Make sure it’s set to heat, turned up a few degrees above the room temperature, and that the batteries aren’t dead. Many thermostats go blank or stop calling for heat when the batteries run low.
If the thermostat looks fine, the problem is often near the boiler. Each zone has either a zone valve, which opens to let hot water through, or its own circulator pump. Zone valve motors and circulators wear out over time, and older homes in our area often still have the original ones. A quick hint: if the pipe for that zone is hot right at the boiler but cold a few feet down the line, the valve may not be opening. That’s a repair we handle regularly.
Make Sure the Heat Can Reach the Room
Baseboard heat works by moving air across thin metal fins inside the cover. Long curtains, furniture pushed against the baseboard and rugs tucked under the cover all slow that airflow. Many baseboard covers also have a small damper along the top that can be closed by accident. Open it fully, and with the heat off and the fins cool, gently vacuum any dust out of the fins.
If the Boiler Isn’t Running at All
Check that the boiler’s power switch is on. On many oil systems it looks like a light switch with a red cover plate, often at the top of the basement stairs. If you heat with oil or propane, check the tank. An empty tank can look like a broken boiler. If the oil burner has a red reset button that’s lit or popped out, press it once and only once. If the burner doesn’t start and stay running, leave it alone and call us. Pressing it again and again can let unburned oil collect inside the boiler and turn a simple repair into a much bigger one.
When to Call Us
Give us a call if you see water on the floor around the boiler, the relief valve is dripping, the boiler makes a rumbling or kettling sound, the burner keeps locking out, or the house is losing heat in freezing weather. You can also read more on our boiler service page.
Many of these problems trace back to service that has been skipped for a few years. ENERGY STAR recommends having your heating system checked every fall, and a yearly boiler visit covers the burner, pressure, relief valve, circulators and zones. Our maintenance page explains what’s included.
Call Noble’s Heating & Cooling at 484-860-2055. Our diagnostic fee is $120 and covers the first half hour on site, which is usually enough time to find the problem. We take calls after hours too, and a home without heat in freezing weather always gets our first attention.